AT 740 FR T30 fire protection door
AT 740
FR T30
T30 · T30-RS · DIN 4102-5 · EN 1634
75 mm
Profile Depth
205 kg
Max. Leaf Weight
1,438 × 3,011 mm
Max. Single-Leaf
RC2
Burglary Resistance
← Fire Door Systems
Fire Protection Systems · T30 / T30-RS

AT 740 FR T30

08 · T30 · T30-RS · DIN 4102-5 / EN 1634 · DIN 18095-1
  • T30 and T30-RS approval per DIN 4102-5 — single- and double-leaf
  • No coolant required — simple processing, close to standard door construction
  • Same profiles and accessories as the AT 740 base system
  • Burglary resistance up to RC2 per EN 1627
  • Smoke protection per DIN 18095-1 · Panic function per DIN EN 179 / EN 1125
System Description
  • The AT 740 FR T30 successfully develops a construction for the highest demands from an established system — combining effective fire and smoke protection with attractive glass and frame design.
  • No coolant required — processing is very simple and barely differs from a standard door.
  • Uses the same profiles and accessories as the AT 740 base system.
  • Fire door leaves up to approx. 1,450 × 3,000 mm can be realised without difficulty.
Technical Features
  • Profile depth: Frame 75 mm · Leaf 75 mm · Glazing bar 75 mm
  • Max. leaf weight: 205 kg
  • Glazing: 15–33 mm with fire-resistant glass
  • Max. leaf size: 1,438 × 3,011 mm
  • Panic function: DIN EN 179 / EN 1125
  • Fire protection: DIN 4102-5 / EN 1634
  • Burglary resistance: EN 1627 up to RC2
  • Smoke protection: DIN 18095-1
Dimensions
Profile depth (frame)75 mm
Profile depth (leaf)75 mm
Profile depth (glazing bar)75 mm
Max. leaf size1,438 × 3,011 mm
Max. leaf weight205 kg
Certifications & Standards
Fire protectionDIN 4102-5 / EN 1634
Smoke protectionDIN 18095-1
Panic functionDIN EN 179 / EN 1125
Burglary resistanceEN 1627 up to RC2
ClassificationT30 · T30-RS
Technical Features
Bautiefen
Rahmen 75 mm, Türflügel 75 mm, Sprossen 75 mm
Flügelgewicht
max. 205 kg
Verglasung
15–33 mm mit Brandschutzglas
Flügelgröße
max. 1.438 × 3.011 mm
Panikfunktion
nach DIN EN 179 / 1125
Brandschutz
nach DIN 4102-5 / EN 1634
Einbruchhemmung
nach EN 1627: bis RC2
Rauchschutz
nach DIN 18095-1
Reference Projects
AT 740 FR T30 reference project AT 740 FR T30 reference DK Metallbau AT 740 FR T30 reference project 2